-40%

NEW Fluke/Wavetek 1362/1362S Precision Digital Multimeter DMM VXI Card/Module

$ 2639.99

Availability: 100 in stock
  • Module Function: Multimeter
  • All returns accepted: ReturnsNotAccepted
  • Brand: Fluke/Wavetek/Datron
  • MPN: 1362S
  • Model: 1362S
  • Condition: This unit is new, old stock surplus from government surplus. It is guaranteed to work for 30-days, parts and labor, excluding freight. This unit has it's original calibration from Novemember, 2007 paperwork but it has expired.

    Description

    NEW Fluke/Wavetek 1362/1362S Precision Digital Multimeter DMM VXI Card/Module
    Comes with what you see in the pictures. If you don't see it, you probably won't get it.
    Specifications are from Fluke and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
    This unit is new, old stock surplus from government surplus. It is guaranteed to work for 30-days, parts and labor, excluding freight. This unit has it's original calibration from Novemember, 2007 paperwork but it has expired.
    1362 Series Basic Configuration:
    Without options, the 1362 is a high quality DC/AC Voltmeter and Ohmmeter. The basic configuration offers the following measurement capabilities:
    DC Voltage in five ranges from 100 nV to 300 V.
    AC Voltage in five ranges from 1 µV to 300 V.
    Resistance in six ranges from 100 µΩ to 20 MΩ.
    Selectable 4.5 to full 6.5 digits resolution.
    Fully IEEE-488.2 programmable, subject to the requirements of the VXI bus message transport system.
    External trigger with trigger delay.
    Autocal: covers-on programmable external calibration.
    1362S Configuration:
    In addition to the features of the 1362, the 1362S can interpret Standard Commands for Programmable Instruments (SCPI Rev. 1991). The Native language can be accessed from SCPI if necessary.
    The instrument also utilizes the VXI backplane trigger bus. The Synchronous and Asynchronous protocols adhere to the VXI revision 1.3 specifications.
    Key Features:
    6.5 digit resolution
    DCV, ACV, and Resistance functions
    1000 readings/second
    Backplane triggers
    SCPI-compatible command
    Single-slot, C-size VXIbus module
    Description:
    The Fluke 1362 is a message based, single-width, C-size card DMM conforming to VXI specification revision 1.4. It provides DCV, ACV, and Ω, with resolutions between 4.5 and 6.5 digits and read rates up to 1000 per second. At high read rates where the system controller may limit the speed of continuous operation, an internal data store can be set to record a block of between 1 and 1000 readings. Dual triggering is provided, using either an internal system trigger or an external TTL level at the front panel or through use of the VXI backplane trigger lines.
    Specifications:
    DC Voltage:
    Ranges:
    100 mV to 300 V in decades.
    Resolution:
    100 nV, 6.5 digits.
    Accuracy:
    90 days, 23°C ±5°C, ± (ppmR + ppmFS). FS = 2 x Range.
    100 mV Range:
    30 + 6.
    1 V Range:
    20 + 3.
    10 V Range:
    20 + 2.
    100 V & 300 V Range:
    30 + 3.
    Read Rate:
    5/s at 6.5 digits, 1000/s at 4.5 digits.
    Input Impedance:
    10 GΩ (0.1 V to 10 V ranges), 10 MΩ (100 V & 300 V ranges).
    CMRR (1 kΩ unbalance):
    > 146 dB at DC > 80 dB + NMRR at 1-60 Hz.
    NMRR:
    Filter out > 54 dB at 50/60 Hz +0.1% filter in add 20 dB to above.
    Protection All Ranges:
    300 V RMS.
    True RMS AC Voltage:
    Ranges:
    100 mV to 300 V in decades.
    Resolution:
    1 µV, 5.5 digits.
    Accuracy:
    90 days, 23°C ±5°C, Signal > 1 %FS, ±(%R + %FS); FS = 2 x Range.
    10 Hz - 40 Hz Range:
    0.4 + 0.1.
    40 Hz  - 20 kHz Range:
    0.035 + 0.01.
    20 kHz - 50 kHz Range:
    0.1 + 0.02.
    50 kHz - 100 kHz Range:
    0.16 + 0.003.
    Hf accuracy:
    (1 V and 10 V ranges, typical).
    100 kHz - 300 kHz:
    ±1 %R + 0.1 %FS.
    300 kHz - 1 MHz:
    ±2 %R + 1 %FS.
    Read Rate:
    12 readings/sec max.
    Input Impedance:
    1 MΩ/100 pF.
    CMRR (1 kΩ unbalance):
    > 80 dB at DC to 60 Hz.
    Crest Factor:
    5:1 at full range.
    Protection at all Ranges:
    300 V RMS.
    Resistance:
    Ranges:
    100 Ω to 10 MΩ in decades.
    Resolution:
    10 µΩ, 6.5 digits
    Accuracy:
    90 days, 23°C ±5°C, ±(ppmR + ppmFS); FS = 2 x Range.
    100 Ω Range:
    35 + 6.
    1 kΩ & 10 kΩ Ranges:
    30 + 3.
    100 kΩ Range:
    40 + 3.
    1 MΩ Range:
    80 + 3.
    10 MΩ Range:
    200 + 4.
    Read Rate:
    As DCV function.
    Protection All Ranges:
    250 V RMS
    Max. Lead Resistance:
    100 Ω in any or all leads.
    Open Circuit Voltage:
    10 V.
    DC Current:
    Range:
    1000 mA.
    Resolution:
    1 µA, 6.5 digits.
    Accuracy:
    90 days, 23°C ±5°C, ±(ppmR + ppmFS); FS = 2 X range.
    Range:
    200 + 10.
    Read Rate:
    as DCV function.
    AC Current:
    Range:
    1000 mA.
    Resolution:
    1 nA, 5.5 digits.
    Accuracy:
    90 days, 23°C ±5°C, ±(R% + %FS).
    10 Hz - 40 Hz:
    0.4 + 0.1.
    40 Hz - 3 kHz:
    0.03 + 0.03.
    Read Rate:
    As ACV function.
    Triggering:
    1362S:
    Selectable front-panel or VXI backplane triggers, including measurement complete. Conforms to VXI synchronous and asynchronous protocol.
    Remote Programming:
    IEEE-488.2 & SCPI.
    General:
    Operating Temperature:
    0°C to +50°C.
    Dimensions:
    Single-slot, C-size: 234 mm H x 340 mm W x 30 mm D (9.2" x 13.4" x 1.2"
    Weight:
    1.6 kg (3.5 lb).
    Power:
    1.5 A (5 V), 0.5 A (±12 V) approx.
    Configuration:
    VXIbus SCPI-compatible DMM (DCV, ACV, Ω).
    For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a .00 minimum for packaging, handling, and order processing. International shipping to be determined by destination.
    Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:
    (1) Are you the end-user of this item?
    (2) If you are not the ultimate end-user of the item, please state the ultimate end user's name.
    (3) What is the ultimate country destination?
    05/28/20